• friendly planing width of 1.000 mm
• application in industry and cooling constructions
• rational solution for designing wall and ceilings
• core-strenght from 120 mm up to cooling-solutions with 200 mm
• „made in Germany”

MANUFACTORING TOLERANCES
DIN EN 14509
All materials used for the panel production correspond to the technical standards and regulations.
The limit dimensions correspond to DIN EN 14509-appendix D.
Element lenght ≤ 3.000 mm ± 5 mm
Element lenght ≥ 3.000 mm ± 10 mm
Element width ± 2 mm
Element strenght ≤ 100 mm ± 2 mm
Element strenght ≥ 100 mm ± 2 %
Lenghtwise and crosswise curvature
2 mm/m lenght, however no more than 10 mm
8.5 mm/m width when smooth profiles h ≤ 10 mm
10 mm/m width when other profile depths h ≥ 10 mm
COVER LAYERS
Outside: Steel sheet 0.6/0.5 mm, ≥ 280 MPa or ≥ 320 MPa, strip galvanized 275 g/m² with 25 µm Polyester painting
(according to DIN 18807 part 3)
Inside: Steel sheet 0.6/0.5 mm, ≥ 280 MPa or ≥ 320 MPa, strip galvanized 275 g/m² with 25 µm Polyester painting
(according to DIN 18807 part 3)
SURFACE PERFORMANCE
Outside: slightly lined, UNICO or smooth
Inside: slightly lined (45.5/45.5), for an extra chrage with smooth inside - however, due to production technical
reasons slight visual limitations possible.
INSULATION CORE
Poly-isocyanurate-rigid foam PIR WLS 023, approx. 96% closed celled, fully connected to steel sheet cover layers.
PRODUCTION LENGTH / WARRANTY
Up to maximum 22.000 mm.
AIRBORNE SOUND INSULATION
Rw(C:Ctr) 25 dB to EN 14509:2007
APPROVAL
• general building approval for use as roof and wall, Z-10.4-658,
DIBt Berlin.
• WATERTIGHTNESS acc. EN 14509, IFT Rosenheim.
• AIR PERMEABELITY acc. EN 12865, EN 1027 and prEN 15601,
IFT Rosenheim.
QUALITY MONITORING
iS -engineering Darmstadt, TU Darmstadt, MFPA Leipzig
ASSOCIATION MEMBER
FIW München, IBU Berlin, IFBS
FACTORY MONITORING
ISO 9001:2008, CE-Kennzeichnung CSI 0497
FIRE PROTECTION
PIR B-s2;d0 according to test EN 13501.1
Euro-Class B-s2;d0
STATICS
See loader tables under www.lattonedil.de in download field ”technical center”.