core-strenght from 40 mm up to 100 mm




• light and stable wall panel and for ceilings
• architectural wall system for demanding designs
• rational solution for designing wall and ceilings
• core-strenght from 40 mm up to 100 mm

MANUFACTORING TOLERANCES
DIN EN 14509
All materials used for the panel production correspond to the technical standards and regulations.
The limit dimensions correspond to DIN EN 14509-appendix D.
Element lenght ≤ 3.000 mm ± 5 mm
Element lenght ≥ 3.000 mm ± 10 mm
Element width ± 2 mm
Element strenght ≤ 100 mm ± 2 mm
Element strenght ≥ 100 mm ± 2 %
Lenghtwise and crosswise curvature
2 mm/m lenght, however no more than 10 mm
8.5 mm/m width when smooth profiles h ≤ 10 mm
10 mm/m width when other profile depths h ≥ 10 mm
COVER LAYERS
Outside: Steel sheet 0.6/0.5 mm, ≥ 280 MPa or ≥ 320 MPa, strip galvanized 275 g/m² with 25 µm Polyester painting
(according to DIN 18807 part 3)
Inside: Steel sheet 0.5/0.4 mm, ≥ 280 MPa or ≥ 320 MPa, strip galvanized 275 g/m² with 25 µm Polyester painting
(according to DIN 18807 part 3)
SURFACE PERFORMANCE
Outside: slightly lined, UNICO or smooth
Inside: slightly lined (45.5/45.5), for an extra chrage with smooth inside - however, due to production technical
reasons slight visual limitations possible.
INSULATION CORE
Poly-isocyanurate-rigid foam PIR WLS 023, approx. 96% closed celled, fully connected to steel sheet cover layers.
PRODUCTION LENGTH / WARRANTY
Up to maximum 22.000 mm, depending on the panel thickness. If panel core between 40 and 80 mm thick,
a maximum delivery lenght of 16.000 mm is recommended, to avoid panel deformations as well as bucklings during (un-)loading and laying.
AIRBORNE SOUND INSULATION
Rw(C:Ctr) 25 dB to EN 14509:2007
APPROVAL
• general building approval for use as roof and wall, Z-10.4-658,
DIBt Berlin.
• WATERTIGHTNESS acc. EN 14509, IFT Rosenheim.
• AIR PERMEABELITY acc. EN 12865, EN 1027 and prEN 15601,
IFT Rosenheim.
QUALITY MONITORING
iS -engineering Darmstadt, TU Darmstadt, MFPA Leipzig
ASSOCIATION MEMBER
FIW München, IBU Berlin, IFBS
FACTORY MONITORING
ISO 9001:2008, CE-Kennzeichnung CSI 0497
FIRE PROTECTION
PIR B-s2;d0 according to test EN 13501.1
Euro-Class B-s2;d0
STATICS
See loader tables under www.lattonedil.de in download field ”technical center”.